SERVICE MANUAL
ADVANCE OVENS
04/02/2020 127
Phase 3 CV operates until TG reaches 61 ºC. When TG falls below 58 ºC, CV enters again until reaching
61ºC, this continues for the period selected by the user. The display shows a countdown for the time
remaining.
Phase 4 VAC operates for 3 minutes.
Phase 5 VDV operates until reaching N.max.
Phase 6 VAC operates for 3 minutes.
Phase 7 VDV operates until reaching N.max.
Phase 8 Steam mode operates until TC reaches 95 ºC.
Lastly, this function ends and the message END DESCALING, is displayed, leaving all outputs at zero (except RG).
The current phase number FX DESCALE and the time remaining are displayed continuously.
If during the descaling cycle the operation is aborted by pressing the descaling button again or because the oven
has been switched off, proceed as follows:
If it has not reached phase 2
The cycle is ended.
If it has reached or exceeded phase 2
The cycle goes to phase 4
If it has reached phase 4
The cycle goes to the phase in which it stopped.
There is an option to abort the descaling process. Press the ON button and then press the START/STOP button for
5 seconds.
Boiler capacities
The chemical product used must have a phosphoric acid base at a concentration of 35 ÷ 40 %. It may contain an
anti-foaming agent. A chemical concentration of approximately 10÷ 5% of the capacity should be used in the boiler.
This concentration depends on the degree of lime scale saturation and the effectiveness of the chemical product.
Please refer to the supplier for advice on the method of application.
17.12.7. HACCP
When the oven is operating with the Core probe or Delta, function, the data with which it is operating must be
stored in order to comply with current legislation with respect to HACCP.
The oven saves all the data for the operating mode, Humidity, TC and TN (the lowest value between TN1 and TN5)
every minute while you remain in the function in question. The data are stored for one month.
These data can be displayed on the screen or downloaded to an external device using a de USB or Ethernet.
Usage:
1. Connect the USB memory stick to the oven when it is switched off.
2. Switch on the oven.
3. Confirm the option START HACCP.
4. After the message END HACCP DOWNLOAD switch off the oven.
5. Remove the USB memory stick.
6. Process the information in the Fagor HACCP application.