SERVICE MANUAL
ADVANCE OVENS
04/02/2020 62
Incorrect installation of the oven may result in the incorrect operation of
the appliance.
Therefore, the drainage Kit supplied (DN50) by the manufacturer should
be installed (Fig. 12). This drainage system should be connected to an
open tank or grille.
Installation (Fig. 13- Fig.14.) should be in such a way as to ensure that the
installed drainage outlet is below the oven outlet with a suitable slope to
ensure drainage (>5% or 3º).
Make sure that the holes on the rising pipe face the side opposite the rear
panel to prevent condensation.
Ensure the measurements for the drainage are correct:
Steam generator pumping volume in a reduced space of time: 0.7
l/s.
Average temperature of waste water: 65 ºC.
.
Table-top models 061-101-102
Floor-mounted models 201 and 202
Once the drainage KIT has been installed, the discharge to the general drainage must be via a type `AA`, `AB` or
`AD` air gap in accordance with EN 1717.
ADVANCE DRAINAGE KIT
The drainage system may be installed using a standard siphon pipe connected to an open tank or grille. For
optimum operation, we recommend you use the manufacturer's drainage KIT, reference 19012125.