SERVICE MANUAL
ADVANCE OVENS
04/02/2020 86
15.21.1. SECTIONS AND OPTIONS OF SETTINGS MENU.
ELECTRIC/GAS
This configures the oven as electric or gas.
DSI = [OPT]
DSD = [OP1]
DII = [E-G]
DID = [ELE] (Electric oven. Default setting)
[GAS] (Gas oven)
MODEL
This configures the size of the oven.
DSI = [OPT]
DSD = [OP2]
DII = [MOD]
DID = [061]
[101]
[201] (Default setting)
[102]
[202]
ºC / ºF
This permits the selection of the required temperature scale.
DSI = [OPT]
DSD = [OP3]
DII = [C-F]
DID = [C] (ºC Default setting)
[F] (ºF)
CONDENSATION
Enables configuration of condensation cycle. It is possible to select how long the condensation is required to be
active for every 10 seconds of the cycle
DSI = [OPT]
DSD = [OP4]
DII = [CND]
DID = [0 ÷10 seconds] (Default setting 2)
CALIBRATION
Option for starting the thermocouple calibration process. To enter, press Humidifier
DSI = [OPT]
DSD = [OP5]
DII = [CAL]
DID = [INI]
When this mode is entered, the following values are displayed:
DSI = [TC] / calibrated value of TC
DSD = [TV] / calibrated value of TV
DII = [TN] / calibrated value of TN
SAT TEST
Option allowing the oven to be set in SAT test mode. To enter, press Humidifier
DSI = [OPT]
DSD = [OP6]
DII = [SAT]
DID = [INI]
To exit this mode go to OUT and confirm with Humidifier