SERVICE MANUAL
ADVANCE OVENS
04/02/2020 117
17.5. TEMPERATURE SELECTION
This section shows the true chamber temperature and that selected by the user.
The temperature shown on the left side of the screen is the true temperature in the chamber.
The temperature shown on the right side of the screen shows the temperature selected by the user.
The range of temperatures for each operating mode is shown below:
Convection: Range (20 ÷ 300 ºC) 160 ºC default setting
Mixed: Range (20 ÷ 250 ºC) 140 ºC default setting
Regeneration: Range (20 ÷ 180 ºC) 120 ºC default setting
Steam: Range (20 ÷ 99 ºC) 99 ºC default setting
Temperature selection: press the central button
which enables the selection using numbers. Select the
required value and confirm or cancel with OK / cancel.
The temperature up
/down buttons allow the temperature setting in the chamber to be modified in units
within the established range. If either of the buttons is pressed for more than 2 seconds, the increase / decrease is
in steps of 10.
When the oven is in delta function these buttons are not displayed.
It is possible to view the true value of the four thermocouples (TC, TV, TN and TG). Therefore, the Power/Speed
button should be pressed for 5 seconds in the Initial Screen.
The oven exits this function when the user releases the button, returning to the values with which it was operating.
17.6. TIME SELECTION
Cooking is according to the temperature and time selected.
1. Select the operating mode.
2. Select the humidity value.
3. Select the required oven temperature.
4. Select the required time
5. Press Start.
The up
/down buttons allow the chamber temperature and time settings to be changed. If either of the
buttons is pressed for more than 2 seconds, the increase / decrease is in steps of 10.
If the oven is on and either of these two buttons is pressed, the remaining time will vary in the same proportion as
the temperature setting is increased / decreased.
On completion of the selected time, a visual/acoustic warning will start. To switch off the alarm, press the
START/STOP button or open the door. If the door is not opened, or if the START/STOP button is not pressed, the
acoustic/visual warning is repeated for 30 seconds every 3 minutes, up to a maximum of 15 minutes