SERVICE MANUAL
ADVANCE OVENS
04/02/2020 137
17.16. SAT MENU
The options available to the SAT technician and the internal operator for the configuration
or inspection of the oven are shown below. To enter, while the oven is in Convection or
Mixed mode, enter 989 in temperature value and 898 in time value.
Blower speed (only for gas ovens): Option to indicate the speed of each blower in gas ovens, between 0 and
8000 rpm, for each operating mode (maintenance speed, starter speed, minimum and maximum power) for
each blower. The increase/decrease of all the speeds is in units of 100.
The default setting for each operating mode is determined by the oven model and the type of gas selected
VCC
o Starter speed (0 ÷ 8000)
o Minimum speed (0 ÷ 8000)
o Maximum speed (0 ÷ 8000)
VCV
o Starter speed (0 ÷ 8000)
o Minimum speed (0 ÷ 8000)
o Maximum speed (0 ÷ 8000)
Table of default convection blower speeds
Natural gas
TOWN GAS
LGP (B/P)
APG-061
Start-up: 4000
Medium: 4200
Maximum: 6500
Start-up: 4000
Medium: 4200
Maximum: 6500
Start-up: 4000
Medium: 3600
Maximum: 5400
APG-101
Start-up Speed: 5000
Medium: 4000
Maximum: 7500
Start-up: 5000
Medium: 4000
Maximum: 7500
Start-up: 5000
Medium: 3600
Maximum: 6000
APG-201
Start-up: 4000
Medium: 4200
Maximum: 8000
Start-up: 4000
Medium: 4000
Maximum: 7200
Start-up: 4000
Medium: 3800
Maximum: 6200
APG-102
Start-up: 4000
Medium: 4000
Maximum: 8000
Start-up: 4000
Medium: 4000
Maximum: 8000
Start-up: 4000
Medium: 3500
Maximum: 6100
APG-202
Start-up: 4000
Medium: 3800
Maximum: 8000
Start-up: 4000
Medium: 4200
Maximum: 8000
Start-up: 4000
Medium: 3500
Maximum: 6000
Table of default steam blower speeds
Natural gas
TOWN GAS
LGP (B/P)