SERVICE MANUAL
ADVANCE OVENS
04/02/2020 139
• Control panel mode Only the interface and outputs RG and LZ operate, all other
inputs/outputs are disabled and all errors are ignored. The values of the TC and TN
probes are fixed.
• Wash Mode The oven runs the intense wash programme and continues in this cycle until
the exhibition mode is exited In this mode, the wash screen is displayed, and all errors are
ignored.
In exhibition mode, the START/STOP button is ignored, as are all the buttons on the screen. The oven can only be
switched off, restoring the wash function when it is switched back on.
To exit the exhibition wash mode, there is a secret sequence (Press START/STOP and then press the Door Icon
button 5 times followed by START/STOP again). If this sequence is entered, the wash box valve is opened to drain
any water contained within, the oven is switched off on conclusion of the operation, disabling this operating mode
for the next system start-up.
• Log Option for viewing the oven log.
The following data should be saved in the log:
o Convection hours Total hours of operation in Convection mode.
o Mixed hours Total hours of operation in Mixed mode.
o Regeneration hours Total hours of operation in Regeneration mode.
o Steam hours Total hours of operation in Steam mode.
o No CC1 Cycles Number of CC1 cycles.
o No CC2 Cycles Number of CC2 cycles.
o No CV1 Cycles Number of CV1 cycles.
o No of CV2 Cycles: Number of CV2 cycles.
o No VDV Cycles Number of VDV cycles.
o No VAC Cycles Number of VAC cycles.
o No VCN Cycles Number of VCN cycles.
o No Ms/Mb Cycles Number of Ms/Mb cycles.
o No Mc/Ma Cycles Number of Ma/Mc cycles.
o No Mba Cycles Number of Mba cycles.
o No VHM Cycles Number of VHM cycles.
o No LZ Cycles Number of LZ cycles.
o No VE Cycles Number of VE cycles.
o No RG Cycles Number of RG cycles.
o No R/L Cycles Number of R/L cycles.
o No M/P Cycles Number of M/P cycles.
o No IP Cycles Number of IP cycles.
o No of Rapid Rinse Cycles.
o No of Rinse Cycles.
o No of Mild Wash Cycles.
o No of Medium Wash Cycles.
o No of Intense Wash Cycles.
o No of Semi-automatic Wash Cycles.
o No of Cool Down Cycles
o Total No of Descaling Cycles
o TC Max Maximum temperature of TC.
o TV Max Maximum temperature of TV.
o TN Max Maximum temperature of TN.
o TG Max Maximum temperature of TG after last descaling.
It is possible to reset all the log data. To do so, press and hold the START/STOP button for 5 seconds.
The data can also be reset one by one. To do so press the Screen ON button for 5 seconds.
• Automatic drainage: Permits the configuration of the frequency with which the oven should drain
the boiler, that is, every so many hours of the oven
’s operation (all modes except convection,
where TG > 60 ºC) the drainage cycle must be run.
1 ÷ 63 (Default setting: 24)