14.5. CATEGORIES, GASES AND OPERATING PRESSURES
AL - BG - DK - EE - FI - HR - LT - LV - MK - NO - RO - SE
CH - CY - CZ - ES - GB - GR - IE - IT - PT - SI - SK - TR
14.6. VENTILATION OF THE PREMISES
The machines must be installed in such a way as to allow adequate ventilation to prevent the unauthorised
concentration in the premises of steam and products emitted during combustion, which may be harmful to health.
The installation of an extraction hood is recommended for the extraction of smoke and steam in accordance with
Standard UNE
–100165:2004. It is advisable that the hood sticks out 200-400 mm from the front part of the
appliance.
14.7. EXTRACTION OF COMBUSTION PRODUCTS
Gas appliances may be installed in different manners depending on the requirements of the installation.
An incorrect connection could result in fire.
14.7.1.
GAS OVEN INSTALLED IN PREMISES (TYPE A3)
We recommend you install the gas oven below the smoke extractor hood.
Install in accordance with local regulations.
The gas supply to the appliance should only be switched on once the extraction
system has been activated.
14.7.2. GAS OVEN BELOW VENTILATION CEILING (TYPE B23)
In this installation, extraction is through a natural draught connection, beneath an
extractor hood or ventilation ceiling.
Install in accordance with local regulations.
The gas supply to the oven should only be switched on once the extraction
system has been activated. If the extraction/ventilation system does not operate
correctly, the gas supply to the oven will be disabled.
Fagor Industrial recommend the annual maintenance by an authorised technician of the components
relating to the gas installation.