SERVICE MANUAL
ADVANCE OVENS
04/02/2020 87
The available inputs/outputs in the oven can be checked and tested individually. When in this mode, select the
required input/output using the temperature selector.
For outputs, use Humidifier to activate the output in question, and Cool Down deactivate it.
For inputs, the status of the selected input is displayed (Yes/No if it is an input which may be active/not active, the
value of the input, etc.)
INPUTS FOR TESTING
If this is a thermocouple, the value it is measuring is shown, or OUT if it does not work. The DID is used to indicate
the input status.
o Chamber probe (TC) DSI =[SAT], DSD=[ E1], DII=[ TC], DID=value
o Steam output probe (TV) DSI=[SAT], DSD=[ E2], DII=[ TV], DID=value
o Core probe (TN) DSI=[SAT], DSD=[ E3], DII=[ TN], DID=value
o Resistance NTC DSI=[SAT], DSD=[ E4], DII=[NTC], DID=value
o Door contactor (IP). DSI=[SAT], DSD=[ E5], DII=[ IP], DID=[YES/NO]
o Gas control signal (HALL). To read the burner blower input, first activate the PWM output with the blower
speed selected. (Only in gas ovens).
DSI=[SAT], DSD=[ E6], DII=[HAL], DID = fan speed x 100
o Variator frequency input (A.E.). To read the variator input, first activate the A.S. output with the speed
selected.
DSI=[SAT], DSD=[ E7], DII=[AE], DID= fan speed x 100
OUTPUTS FOR TESTING
o Chamber heating (CC1) DSI=[SAT], DSD=[ S1], DII=[CC1], DID=[YES/NO]
o Chamber heating (CC2) DSI=[SAT], DSD=[ S2], DII=[CC2], DID=[YES/NO]
o Fan on (M/P) DSI=[SAT], DSD=[ S3], DII=[ MP], DID=[YES/NO]
o Fan direction (I/D) DSI=[SAT], DSD=[ S4], DII=[ ID], DID=[LEF/RIG]
o Condensation solenoid valve (VCN) DSI=[SAT], DSD=[ S5], DII=[VCN], DID=[YES/NO]
o Humidifier solenoid valve (VHM) DSI=[SAT], DSD=[ S6], DII=[VHM], DID=[YES/NO]
o Fluepipe motor (Ms/Mb) DSI=[SAT], DSD=[ S7], DII=[MSB], DID=[MS/MB]
o Main supply relay (RG) DSI=[SAT], DSD=[ S8], DII=[ RG], DID=[YES/NO]
o Fan (VE) DSI=[SAT], DSD=[ S9], DII=[ VE], DID=[YES/NO]
o Oven lighting (LZ) DSI=[SAT], DSD=[S10], DII=[ LZ], DID=[YES/NO]
o Buzzer (TA) DSI=[SAT], DSD=[S19], DII=[ TA], DID=[YES/NO]
All the outputs are in OFF mode, and switch to ON when activated by the user.
LOG
Option for viewing the oven log. To enter, press Humidifier.
DSI = [OPT]
DSD = [OP7]
DII = [HIS]
DID = [INI]
The following data has been saved in the log. They should be displayed as follows if you enter view data. To go
from one section to the next, use the temperature selector.
Steam hours Total hours of operation in Steam mod
DSI = [HIS], DSD = [HMS], DII+DID = value
Mixed hours Total hours of operation in Mixed mode
DSI = [HIS], DSD = [HMM], DII+DID = value
Convection hours Total hours of operation in Convection mode.
DSI = [HIS], DSD = [HMC], DII+DID = value
No CC1 Cycles Number of CC1 cycles.
DSI = [HIS], DSD = [CC1], DII+DID = value