SERVICE MANUAL
ADVANCE OVENS
04/02/2020 91
TABLE OF DEFAULT BLOWER SPEEDS
ACG-061
Medium: 4200
Medium: 3600
Medium:
ACG-101
Medium: 4000
Medium: 3600
Medium:
ACG-201
Medium: 4200
Medium: 3800
Medium:
ACG-102
Medium: 4000
Medium: 3500
Medium:
ACG-202
Medium: 3800
Medium: 3500
Medium:
RELIABILITY
Option permitting the oven to be changed to Reliability mode in order to check the reliability of the different
components of the oven. To do so, one of the four pre-established programmes should be selected.
DSI = [OPT]
DSD = [O22]
DII = [FIA]
DID = [1÷ 5] (Default setting 1)
To exit this mode, press the Cool Down and Humidifier buttons together for 5 seconds.
Reliability programme 1
This is the sequence which should be repeated:
o 8 minutes Convection Mode at 120 ºC.
o 8 minutes Mixed Mode at 110 ºC.
o 8 minutes Steam Mode.
Display: True operating parameters
The true value of the thermocouples can be displayed by pressing Cool Down for 5 seconds..
Reliability programme 2
The oven will operate in Convection Mode at 300 ºC. The fluepipe is activated every 30 seconds, going up or down
depending upon the initial position.
Display:
DSI = value TC
DSD = 300
DII and DID = No of fluepipe cycles
The true value of the thermocouples can be displayed by pressing Cool Down for 5 seconds.
Reliability programme 3
The oven operates in Convection Mode at 300ºC.
Display:
DSI = value TC
DSD = 300
DII = value NTC
DID = This indicates whether the VE output is active or not. [ON] / [OFF]
The true value of the thermocouples can be displayed by pressing Cool Down for 5 seconds.
Reliability programme 4