SERVICE MANUAL
ADVANCE OVENS
04/02/2020 91
TABLE OF DEFAULT BLOWER SPEEDS
NATURAL GAS ( G20)
LPG (B/P) ( G30/31)
CITY GAS ( G-110 )
ACG-061
Start-up: 4000
Medium: 4200
Maximum: 6500
Start-up: 4000
Medium: 3600
Maximum: 5400
Start-up:
Medium:
Maximum:
ACG-101
Start-up Speed: 5000
Medium: 4000
Maximum: 7500
Start-up: 5000
Medium: 3600
Maximum: 6000
Start-up:
Medium:
Maximum:
ACG-201
Start-up: 4000
Medium: 4200
Maximum: 8000
Start-up: 4000
Medium: 3800
Maximum: 6200
Start-up:
Medium:
Maximum:
ACG-102
Start-up: 4000
Medium: 4000
Maximum: 8000
Start-up: 4000
Medium: 3500
Maximum: 6100
Start-up:
Medium:
Maximum:
ACG-202
Start-up: 4000
Medium: 3800
Maximum: 8000
Start-up: 4000
Medium: 3500
Maximum: 6000
Start-up:
Medium:
Maximum:
RELIABILITY
Option permitting the oven to be changed to Reliability mode in order to check the reliability of the different
components of the oven. To do so, one of the four pre-established programmes should be selected.
DSI = [OPT]
DSD = [O22]
DII = [FIA]
DID = [1÷ 5] (Default setting 1)
To exit this mode, press the Cool Down and Humidifier buttons together for 5 seconds.
Reliability programme 1
This is the sequence which should be repeated:
o 8 minutes Convection Mode at 120 ºC.
o 8 minutes Mixed Mode at 110 ºC.
o 8 minutes Steam Mode.
Display: True operating parameters
The true value of the thermocouples can be displayed by pressing Cool Down for 5 seconds..
Reliability programme 2
The oven will operate in Convection Mode at 300 ºC. The fluepipe is activated every 30 seconds, going up or down
depending upon the initial position.
Display:
DSI = value TC
DSD = 300
DII and DID = No of fluepipe cycles
The true value of the thermocouples can be displayed by pressing Cool Down for 5 seconds.
Reliability programme 3
The oven operates in Convection Mode at 300ºC.
Display:
DSI = value TC
DSD = 300
DII = value NTC
DID = This indicates whether the VE output is active or not. [ON] / [OFF]
The true value of the thermocouples can be displayed by pressing Cool Down for 5 seconds.
Reliability programme 4

Table of Contents