SERVICE MANUAL
ADVANCE OVENS
04/02/2020 107
0 ÷ 10 (Default setting: 2 seconds)
TABLE OF DEFAULT CONVECTION BLOWER SPEEDS
AG-061
Medium: 4200
Medium: 4200
Medium: 3600
AG-101
Medium: 4000
Medium: 4000
Medium: 3600
AG-201
Medium: 4200
Medium: 4000
Medium: 3800
AG-102
Medium: 4000
Medium: 4000
Medium: 3500
AG-202
Medium: 3800
Medium: 4200
Medium: 3500
TABLE OF DEFAULT STEAM BLOWER SPEEDS
AG-061
Medium: Tg>90ºC, -
15%Max
Medium: 5000
Maximum: 5000
Medium: Tg>90ºC, -
15%Max
AG-101
Medium: Tg>90ºC, -
15%Max
Medium: 6600
Maximum: 6600
Medium: Tg>90ºC, -
15%Max
AG-201
Medium: Tg>90ºC, -
15%Max
Medium: 6200
Maximum: 6200
Medium: Tg>90ºC, -
15%Max
AG-102
Medium: Tg>90ºC, -
15%Max
Medium: 6200
Maximum: 6200
Medium: Tg>90ºC, -
15%Max
AG-202
Medium: Tg>90ºC, -
15%Max
Medium: 8000
Maximum: 8000
Medium: Tg>90ºC, -
15%Max
o M49 Auto. Auto Permits the configuration of the frequency with which the oven should drain the boiler, that
is, every so many hours of the oven
’s operation (all modes except convection, where TG > 60 ºC) the
drainage cycle must be run.
1 ÷ 63 hours (Default setting: 24 hours)
M68 Draining This message is displayed when the appliance is draining.
M69 Max Level This message is displayed when, during the drainage cycle, the level detecting rods
detect maximum level.
M70 Min Level This message is displayed when, during the drainage cycle, the level detecting rods detect
minimum level.
M71 Below Min This message is displayed when, during the drainage cycle, the level detecting rods
detect the level is below the minimum.
M72 End Drainage This message is displayed when the drainage cycle is completed.