SERVICE MANUAL
ADVANCE OVENS
04/02/2020 140
There is an option to abort the process by pressing START/STOP for 5 seconds.
Condensation time: Option for configuring the condensation cycle. To do so, the technician may
select how long the condensation is required to be active for every 10 seconds of the cycle. Range
[0 ÷ 10], 2 default setting.
SAT test: Access to a new screen where the technician can test each of the oven components.
Update Software: Process for updating the control panel software. Insert a USB memory stick
containing the new version
Calibrate thermocouples: Start the thermocouple calibration process, selecting the required time
(from 10 to 300 seconds, 30
and 120by default in electric and gas ovens respectively). This is
the time during which the probes must be stabilised without changing their value.
When this function is activated, the value of the 4 thermocouples (TC, TV, TG, TN) is displayed.
The 4 thermocouples should measure between 80 and 110 ºC.
First, the oven is set to Steam mode until TC reaches 99 degrees. This step is considered
preliminary to calibration and should not be counted in the calibration time.
Next, operate the CV output continuously so that the TC, TN, TV (only in electric ovens) and TG probes
measure values between 80 and 110 ºC. When all the values measured by the probes have been determined (CV
takes the set time without a break while running, without any value changing more than one degree), the probes are
taken as a reference from 100ºC, and all the thermocouples are calibrated. Therefore, the difference of all the
values with respect to 100 is noted. This value is used to adjust subsequent displays of the thermocouples.
If the calibration cannot be completed within 15 minutes, the corresponding error is displayed.
The user may abort the thermocouple calibration process at any moment.
Manual drainage: Option permitting the drainage of the boiler.
If the user does not abort the operation (leaving the screen), the drainage cycle automatically stops after 3
minutes.
Activating Factory Configuration: Option to return to factory configuration of the oven, resetting
these values.
Blower Speed Blowers
Oven model (VPE 201)
Gas type (B/P)
Automatic drainage (24)
Condensation time (2)
Delta value (50)
Config. Display (date and time active, screensaver off)
Temperature scale (ºC)
Locking (0)
Thermal stop (No)
Erase all new recipes created by the user
Tester number: Option allowing the number of the person who has tested the oven to be entered or
displayed. Sequence of 3 numbers.
Error log: This displays all the errors which have been produced in the oven, indicating the error,
date and time of the error
There is an option to reset the log by pressing START/STOP for 5 seconds.
The data can also be reset one by one. To do so press the Screen ON button for 5 seconds
o Settings: To enter this mode for internal use by Fagor Industrial, a sequence must be entered
While the oven is in convection mode, enter 987 in
temperature valueand 876 in time value.