15.22. TYPES OF FAULT
When an error occurs:
The bell rings intermittently.
The code and error identification are displayed in the oven windows.
If the START/STOP, button is pressed, the error message continues to be displayed but the bell stops
ringing.
When the fault causing the error is removed, the outputs return to normal operation.
The errors which may occur in the oven are listed below, together with the message displayed and the impact on
the operation of the oven.
ERROR DESCRIPTION CONSEQUENCE
001
Camera probe broken. TC
out of range (-5÷330 ºC).
The oven is completely disabled.
002
Core probe (TN) damaged.
TN out of range (-10÷330
ºC).
The spike and delta function is disabled.
003
Steam outlet temperature
probe (TV) faulty. TV out
of range (-5÷330 ºC).
It is only possible to operate in
Convection mode, omitting water
condensation.
010
If the VHM outlet is
activated and TV does not
rise 3 or more degrees in 2
minutes, if TV<=75 ºC.
It is only possible to operate in
Convection mode.
011
The CC output operates for
23 minutes and TC does
not rise 3 or more degrees.
(Tc=T Setting -10ºC).
The oven is completely disabled.
012
The NTC of controller
reaches 60 ºC, but does
not exceed 70 ºC.
The oven operates normally and the bell
is not heard. This message should be
displayed every 3 minutes for 30
seconds.
013 (only ACG) Chamber blower error. The oven is completely disabled.
014 (only ACG)
Chamber ignition control
blocked.
The oven is completely disabled.
015 (ACG)
Fault in the chamber
ignition circuit.
The oven is completely disabled.
022
The NTC of controller
exceeds 70 ºC.
The oven is completely disabled.
024
Communication error. The
chamber card does not
respond.
The oven is completely disabled.
025
Communication error. The
control holder card does
not respond.
The oven is completely disabled.