Installation manual
CNC 8035
11.
ACCESS TO INTERNAL CNC VARIABLES
Other variables
(SOFT M: V15.3X)
(S
OFT T: V16.3X)
·392·
ORGROT
This variable can only be used at the mill model. It returns the rotation angle of the coordinate system
currently selected with G73. Its value in 0.0001 degree units.
PRBST
Returns probe status.
0 = the probe is not touching the part.
1 = the probe is touching the part.
CLOCK
Returns the time in seconds indicated by the system clock. Possible values 0..4294967295.
TIME
Returns the time in hours-minutes-seconds format.
(CNCRD TIME, R100, M102) ; assigns the time to register R100. For example, if the time is 18h
22m 34s, R100 will show 182234.
DATE
Returns the date in year-month-day format.
(CNCRD DATE, R101, M102) ; assigns the date to register R101. For example: if the date is April
25th 1992, R101 = 920425.
CYTIME
It returns the amount of time (in hundredths of a second) elapsed executing the part. It ignores the
time the execution has been interrupted. Possible values 0..4294967295.
The CNC will consider the execution of the program finished after executing its last block or after
executing a block containing an M02 or M30 miscellaneous function.
FIRST
Indicates whether it is the first time that a program has been run or not. It returns a value of 1 if it
is the first time and 0 if not.
A first-time execution is considered as being one which is done:
After turning on the CNC.
After pressing [SHIFT]+[RESET].
Every time a new program is selected.
ANAIn
It returns the status in tenths of a volt (±5 V range) of the indicated analog input (n) and it is possible
to select one of the 8 analog inputs (1 through 8).
CNCERR
Returns the Error code active at the CNC. If none, it returns "0".
DNCERR
Returns the Error code generated via DNC. If none, it returns "0".
DNCSTA
DNC transmission status, even when not having this option. There is on bit that will be set to ·1· when
a transmission is in progress.