EasyManua.ls Logo

Fagor CNC 8055i FL EN - Heat Dissipation by Flowing Air to the Outside with a Fan

Fagor CNC 8055i FL EN
732 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
·110·
Installation manual
CNC 8055
CNC 8055i
3.
HEAT DISSIPATION
SOFT: V02.2X
Heat dissipation by flowing air to the outside with a fan
3.3 Heat dissipation by flowing air to the outside with a fan
Heat dissipation by convection forcing hot air flow to flow outside with a fan and ambient air input
through the holes of the bottom surface of the enclosure.
For this case, calculate the necessary air flow that the fan must supply to dissipate the heat
generated inside the enclosure. The fan's air flow is calculated according to the power dissipated
by the CNC and the fan itself as well as the inside and outside temperatures.
Bear in mind that this air flow through the unit extracts hot air to the outside, but it allows dirt into
the enclosure. Thus, a filter should be installed to maintain the ambient conditions allowed.
Surface without paint.