Installation of the modules
4.1 Installation of the modules
Place the modules on 2 profiles, according to the UNE 50022 standard, with 2 securing ends, one
at each end of the group; they help securing the modules besides maintaining the right gap between
the profiles.
Dimensions of the modules
Always leave a 140 mm gap under the modules for ventilation and later handling.
Connection of the modules
The modules of the group are connected as follows:
A. For ground connection.
B. Ribbon cable to interconnect the modules.
C. Securing studs.
Each group is connected to the system (CPU, Keyboard, etc.) through the CAN bus as described
later on.