Installation manual
CNC 8055
CNC 8055i
REMOTE MODULES (BUS CAN WITH CANOPEN PROTOCOL)
4.
SOFT: V02.2X
·115·
Power supply
Description of the connectors (power supply)
Connector ·X1·. Power supply.
3-pin male Phoenix connector (7.62 mm pitch).
POWER
ANALOG I/O
X1
CHS
GN D
24V
SPEED
1
0
ADDRESS
ERR
RUN
CAN
0
1
LT
GN D
L
SH
H
SH
GN D
L
SH
H
SH
X2
X3
01
01
SH
X4
RL1
R1
R1
RF1
SH
X5
12
I1
I1
SH
12
GN D
X6
Connector ·X6·.
4 differential analog inputs.
Connector ·X4·.
4 general purpose analog
outputs.
Connector ·X5·.
2 PT100 inputs.
Connector ·X1·.
Power supply.
Connector ·X2·.
CAN bus connection.
·SPEED· selector.
CAN bus transmission speed.
·Line Term· selector.
Line terminating resistor.
·ADDRESS· selector.
Address (node) of the element within the CAN
bus.
·X3· connector.
CAN bus connection.
Leds.
Status indicators.
Power supply with analog
inputs and outputs.
Pin Signal and function
1 Chassis Shield.
2 11 Power supply.
3 + 24 V Power supply.
CHS
GND
24V