Installation manual
CNC 8055
CNC 8055i
REMOTE MODULES (BUS CAN WITH CANOPEN PROTOCOL)
4.
SOFT: V02.2X
·117·
Power supply
·Line Term· selector.
Line terminating resistor. The "Line_Term" switch identifies which are the elements that occupy the
ends of the CAN bus; i.e. the first and last physical element in the connection.
The switch of the elements at the ends must be in the ·1· position and the rest of the elements in
the ·0· position.
The central unit must always be at one end of the line. The other end will be the last one of the remote
module groups.
Description of the connectors (digital inputs and outputs)
Connector ·X4· & ·X5·. Digital outputs (8 outputs in each connector).
10-pin male Phoenix minicombicon connector (3.5 mm pitch).
Both connectors must be powered with 24 V DC and GND.
Connector ·X6· & ·X7·. Digital inputs (12 inputs in each connector).
12-pin male Phoenix minicombicon connector (3.5 mm pitch).
Signal Function
+ 24 V Power supply.
O1 - O8 Digital outputs.
O9 - O16 Digital outputs.
11 Power supply.
Signal Function
I1 - I12 Digital inputs.
I13 - I24 Digital inputs.
O1
+24V
X4
GN D
O8
O2
O3
O4
O5
O6
O7
O9
+24V
X5
GN D
O16
O10
O11
O12
O13
O14
O15
I12
I1
I24
I13
X6 X7
I2
I3
I4
I5
I6
I7
I8
I9
I10
I11 I23
I22
I21
I20
I19
I18
I17
I16
I15
I14

Table of Contents