·118·
Installation manual
CNC 8055
CNC 8055i
4.
REMOTE MODULES (BUS CAN WITH CANOPEN PROTOCOL)
SOFT: V02.2X
Power supply
Description of the connectors (analog inputs and outputs)
Connector ·X4·. General purpose analog outputs (4 outputs).
12-pin male Phoenix minicombicon connector (3.5 mm pitch).
Each analog output has three pins (O+, O-, SH). Use shielded cables connecting their meshes to
the corresponding shield pin.
Connector ·X5·. Inputs for the temperature sensor PT100 (2 inputs).
10-pin male Phoenix minicombicon connector (3.5 mm pitch).
Each input has 5 pins (RL, R+, R-, RF1, SH). Use shielded cables connecting their meshes to the
corresponding shield pin.
Signal Function
O1+ O1- Analog output.
O2+ O2- Analog output.
O3+ O3- Analog output.
O4+ O4- Analog output.
SH Shield connection.
Signal Function
R1+ R1-
RL1 RF1
Signals of the PT100 sensor.
R2+ R2-
RL2 RF2
Signals of the PT100 sensor.
SH Shield connection.
SH
O1+
X4
O1-
SH
O2+
O2-
SH
O3+
O3-
SH
O4+
O4-
X5
R1+
RL1
SH
RF2
R1-
RF1
SH
RL2
R2+
R2-
R1+
R1-
RL1
RF1
4 wires. 3 wires. 2 wires.
R1+
R1-
RL1
RF1
R1+
R1-
RL1
RF1