Installation manual
CNC 8055
CNC 8055i
REMOTE MODULES (BUS CAN WITH CANOPEN PROTOCOL)
4.
SOFT: V02.2X
·119·
Power supply
Connector ·X6·. Differential analog inputs (4 inputs).
15-pin male Phoenix minicombicon connector (3.5 mm pitch).
Each analog input has three pins (I+, I-, SH). Use shielded cables connecting their meshes to the
corresponding shield pin.
Signal Function
I1+ I1- Analog input
I2+ I2- Analog input
I3+ I3- Analog input
I4+ I4- Analog input
SH Shield connection.
+12
-12
11
Reference outputs.
+12
I1+
I1-
SH
GN D
X6
I2+
I2-
SH
I3+
I3-
I4+
I4-
-12
SH
SH