·124·
Installation manual
CNC 8055
CNC 8055i
4.
REMOTE MODULES (BUS CAN WITH CANOPEN PROTOCOL)
SOFT: V02.2X
Electrical characteristics of the inputs and outputs
4.5 Electrical characteristics of the inputs and outputs
Digital inputs
All digital inputs are galvanically isolated through opto-couplers. The electrical characteristics of the
inputs are:
Digital outputs
All digital outputs are galvanically isolated through opto-couplers. The electrical characteristics of
the outputs are:
The digital outputs have a fuse inside for protection against over-voltage (over 33 V DC) and against
reverse connection of the power supply.
Analog inputs
Use shielded cables connecting their meshes to the corresponding shield pin. All the analog inputs
have the following characteristics:
Analog outputs
Use shielded cables connecting their meshes to the corresponding shield pin. All the analog outputs
have the following characteristics:
Rated voltage +24 V DC (between +18 V DC and +30 V DC).
High threshold "1" Over +18 V DC.
Low threshold "0" Under +9 V DC.
Typical consumption of each input 5 mA.
Maximum consumption of each input 7 mA.
Rated voltage +24 V DC (between +18 V DC and +30 V DC).
Output voltage 2 V less than the supply voltage.
Maximum output current 500 mA per output.
Voltage range ±10 V
Resolution 12 bits
Input impedance 20 k
Maximum cable length (unshielded) 75 mm.
Command voltage range ±10 V
Resolution 16 bits
Minimum impedance of the connected device 10 k.
Maximum cable length (unshielded) 75 mm.