·126·
Installation manual
CNC 8055
CNC 8055i
4.
REMOTE MODULES (BUS CAN WITH CANOPEN PROTOCOL)
SOFT: V02.2X
Numbering of the digital inputs and outputs
4.6 Numbering of the digital inputs and outputs
The following PLC machine parameters identify each of the 4 possible remote modules. The
following group of parameters must be defined for each one of them.
IOCANID* Node address.
ICAN* Number of digital inputs of the group.
OCAN* Number of digital outputs of the group.
NUICAN* Number of the first digital input of the group.
NUOCAN* Number of the first digital output of the group.
IANALOG* Number of analog inputs of the group.
OANALOG* Number of analog outputs of the group.
PT100_* Number of physical connections for PT100 probes of the group.
NUIANA* Number of the first analog input of the group.
NUOANA* Number of the first analog output of the group.
Refer to the parameters and examples of how to set the remote modules. See "6.9 PLC Parameters"
on page 277.