CNC 8055
CNC 8055i
SOFT: V02.2X
5
·127·
MACHINE AND POWER
CONNECTION
Mains connection of the 8055 CNC’s central unit
It has a three-prong plug for mains and ground connection.
Power the central unit through a separate 110VA transformer with an output voltage between 84
V AC and 264 V AC and 50-60 Hz.
The monitor & keyboard unit must be powered with 220Vac.
Mains connection of the 8055i CNC’s central unit
The "Central Unit + Monitor" set has a three-prong male Phoenix connector with a 7.62 mm pitch.
Use an independent external power supply with the following specifications:
The central unit has a protection against overvoltage that activates at 36 V.
Power switch.
This power switch must be mounted in such a way that it is easily accessed and at a distance
between 0.7 meters (27.5 inches) and 1.7 meters (5.5ft) off the floor.
Install this unit in the proper place.
It is recommended, whenever possible, to install the CNC away from coolants, chemical product,
blows, etc. that could damage it.
Pin Signal and function
1 + 24 V Power supply.
2 0 V Power supply.
3 Chassis Shield.
Rated voltage 20 V minimum 30 V maximum
Ripple: 4 V
Nominal current 2 A
Current peak on power-up: 8 A