5.
MACHINE AND POWER CONNECTION
SOFT: V02.2X
Connection of the emergency input and output
When the CNC detects an error, it will let the PLC know through the general logic output "/ALARM"
and it will activate the emergency output (logic level 0).
Pin 2 of connector X10 of the –Axes– module.
Since this signal corresponds to the PLC output O1, it can also be activated by the PLC program.
The recommended connection diagram is the following:
Emergency STOP
Emergency output
Emergency STOP relay
Emergency from
electrical cabinet
Other emergency
buttons
O1
I1
RE
RSE
RSE
0 V
24 V
0 V
RE
Emergency
STOP button