·248·
Installation manual
CNC 8055
CNC 8055i
6.
MACHINE PARAMETERS
SOFT: V02.2X
Spindle parameters
LOOPCHG (P26)
Indicates the sign of the velocity command. If correct, leave it as is, but to change it, select YES if
it was set to NO and viceversa.
MINANOUT (P27)
Indicates the minimum value for the spindle velocity command.
SERVOFF (P28)
Defines the velocity command offset value for the drive.
The scale for the following error is 10m per square.
• Proper adjustment with Feed-forward.
• Wrong adjustment with Feed-forward.
Possible values
NO / YES.
Default value: EZ
Possible values
It is given in D/A converter units and it admits integer values between 0 and 32767 which corresponds
to an analog command of 10V.
Default value: 0
MINANOUT Minimum velocity command
1
- - -
3277
- - -
32767
0.3 mV.
- - -
1 V.
- - -
10 V.
Possible values
It is given in D/A converter units and it admits integer values between 0 and ±32767 which corresponds
to an analog command of 10V.
Default value: 0 (not applied)