Spindle parameters
LOSPDLIM (P29) UPSPDLIM (P30)
Indicate the upper and lower limits of the actual spindle speed so the CNC can "notify" the PLC (by
means of the "REVOK" signal) that the actual spindle rpms are the same as the programmed ones.
DECINPUT (P31)
Indicates whether or not the spindle has a home switch to synchronize the spindle when working
in M19.
REFPULSE (P32)
Indicates the type of marker pulse Io to synchronize the spindle when working in M19.
REFDIREC (P33)
Indicates the rotating direction when synchronizing the spindle during M19.
REFEED1 (P34)
Indicates the spindle’s positioning speed when in M19 and the synchronizing speed until it finds the
home switch.
SERVOFF Command
-32767
- - -
-3277
- - -
1
- - -
3277
- - -
32767
-10 V.
- - -
-1 V.
- - -
0.3 mV.
- - -
1 V.
- - -
10 V.
Possible values
Integer numbers between 0 and 255.
Default value: For LOSPDLIM (P29) = 50%.
Default value: For UPSPDLIM (P30) = 150%.
Value Meaning
EZ It has no home switch.
YES It has a home switch.
Default value: YES
Value Meaning
+ sign Positive pulse (5 V).
- sign Negative pulse (0 V).
Default value: + sign
Value Meaning
+ sign Positive direction.
- sign Negative direction.
Default value: + sign
Possible values
Between 0.0001 degrees/min and 99999.9999 degrees/min.
Default value: 9000 degrees/min.