Loading...
Installation manual
CNC 8055
CNC 8055i
MACHINE PARAMETERS
6.
SOFT: V02.2X
·263·
Spindle parameters
6.5.2 Machine parameters for auxiliary spindle
MAXSPEED (P0)
Indicates the maximum speed of the auxiliary spindle.
SPDLOVR (P1)
It indicates whether the spindle override keys of the operator panel modify or not the speed of the
auxiliary spindle when it is active.
MINANOUT (P2)
It sets the minimum velocity command value.
SERVOFF (P3)
Defines the velocity command offset value for the drive.
Possible values
Values with 3 decimals between 0.000 and 200000.000 rpm.
Default value: 1000 rpm.
Value Meaning
EZ They have no effect.
YES SINMAGNI = 360 / (3600 x 0.001) = 100 The CNC will apply the values set for main
spindle parameters "MINSOVR" (P10), "MAXOVR" (P11) and "SOVRSTEP" (P12).
Default value: NO.
Possible values
It is given in D/A converter units and it admits integer values between 0 and 32767 which corresponds
to an analog command of 10V.
Default value: 0
MINANOUT Minimum velocity command
1
- - -
3277
- - -
32767
0.3 mV.
- - -
1 V.
- - -
10 V.
Possible values
It is given in D/A converter units and it admits integer values between 0 and ±32767 which corresponds
to an analog command of 10V.
Default value: 0 (not applied)
SERVOFF Command
-32767
- - -
-3277
- - -
1
- - -
3277
- - -
32767
-10 V.
- - -
-1 V.
- - -
0.3 mV.
- - -
1 V.
- - -
10 V.

Table of Contents