·270·
Installation manual
CNC 8055
CNC 8055i
6.
MACHINE PARAMETERS
SOFT: V02.2X
Serial line parameters
PROTOCOL (P4)
Indicates the type of communications protocol to be used.
PWONDNC (P5)
Indicates whether the DNC feature will be active on power-up or not.
DNCDEBUG (P6)
Indicates whether the debugging feature for DNC communications is active or not.
It is advisable to use this safety feature in all DNC communications. It could be deactivated in the
debugging process.
ABORTCHR (P7)
Indicates the character used to abort communications with general peripheral device.
EOLCHR (P8)
Indicates the character used to indicate "end of line" when communicating with general peripheral
device.
Value Meaning
0 Communications protocol for general device.
1 DNC communications protocol.
2 Communications protocol for Fagor floppy disk unit.
3 Open communication.
Default value: 1 (DNC)
Value Meaning
EZ Not active on power-up.
YES Active on power-up
Default value: YES
Value Meaning
EZ Debug NOT active. Communication aborted.
YES Debug active. Communication not aborted.
Default value: EZ
Value Meaning
0CAN
1EOT
Default value: 0
Value Meaning
0LF
1RC
2LF-CR
3 CR-LF
Default value: 0