Installation manual
CNC 8055
CNC 8055i
MACHINE PARAMETERS
6.
SOFT: V02.2X
·273·
Ethernet parameters
DNCEACT (P22)
DNC number to be used by Ethernet.
IPTYPE (P23)
Reserved. It must be set to "0".
DIRIP (P24)
IP address of the CNC.
NETMASK (P25)
Network mask.
IPGATWAY(P26)
Gateway IP address.
IPWDNC (P27)
WinDNC server's IP address.
The WinDNC server is the external device to connect with via DNC. This device may be a CNC,
or a PC with WinDNC.
Defining it as 0.0.0.0 does not allow transferring from the CNC, but it is possible from the PC.
Value Meaning
0 There is no active DNC associated with Ethernet.
1 DNC 1 associated with Ethernet.
2 DNC 2 associated with Ethernet.
The RS-232 serial line is disabled.
Default value: 1
Possible values
Four numbers between 0 and 255 separated by dots.
Default value: 0.0.0.0 (the network is not activated)
Possible values
Four numbers between 0 and 255 separated by dots.
Default value: 0.0.0.0 (the network is not activated)
Possible values
Four numbers between 0 and 255 separated by dots.
Default value: 0.0.0.0 (it has no gateway)
Possible values
Four numbers between 0 and 255 separated by dots.
Default value: 0.0.0.0