·282·
Installation manual
CNC 8055
CNC 8055i
6.
MACHINE PARAMETERS
SOFT: V02.2X
PLC Parameters
IANA5V (P130)
On an 8055 CNC with –Vpp Axes– module, this parameter indicates the range to be used in each
differential analog input of the module's connector X7. A range of ±5 V or ±10 V may be assigned
for each analog input.
This parameter has 16 bits counted from right to left.
Each bit has a function or work mode associated with it. Assigning the value of ·1· activates the
corresponding function. The default value for bits 13 to 16 is ·1· (±5 V range).
Bit 12 - 15. Average range for the analog inputs.
These bits refer to the 4 analog inputs of the –Vpp Axes– module. Every bit corresponds to an analog
input and indicates whether it uses a ±5 V range (bit=1) or a ±10 V range (bit=0).
NUILO1 (P131) NUOLO1 (P132) NUILO2 (P133)
NUOLO2 (P134) NUILO3 (P135) NUOLO3 (P136)
NUILO4 (P137) NUOLO4 (P138)
These PLC machine parameters may be used to redefine the numbering of the inputs/outputs of
the local expansion modules without having to modify the PLC program.
The first I/O module is always the CPU (8055i CNC without expansion board) or an axes board or
an I/O board (modular 8055 CNC). Note that this first module is not an expansion module.
In either case, the first input number is always I1 and the first output number O1 and they cannot
be set by parameters.
IMPORTANT: The numbering of both the first local input and the first local output of any expansion
module must be a multiple of 8 plus 1 (1+ 8n).
Inside the expansion module, the numbering of the rest of inputs/outputs will be sequential from the
first one on.
The inputs/outputs of the expansion modules will be numbered differently depending on the values
entered in parameters NUILOn and NUOLOn (with n= 1, 2, 3, 4).
Bit Meaning
0 - 11 Not used.
12 Analog input 4 (±5 V range).
13 Analog input 3 (±5 V range).
14 Analog input 2 (±5 V range).
15 Analog input 1 (±5 V range).
Default value: 1111000000000000
bit
15
14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Value Meaning
NUILO1 Numbering of the first input of the first expansion module with inputs/outputs.
NUOLO1 Numbering of the first output of the first expansion module with inputs/outputs.
NUILO2 Numbering of the first input of the second expansion module with inputs/outputs.
NUOLO2 Numbering of the first output of the second expansion module with inputs/outputs.
NUILO3 Numbering of the first input of the third expansion module with inputs/outputs.
NUOLO3 Numbering of the first output of the third expansion module with inputs/outputs.
NUILO4 Numbering of the first input of the fourth expansion module with inputs/outputs.
NUOLO4 Numbering of the first output of the fourth expansion module with inputs/outputs.
If incoherent parameter settings are detected on power-up, an error message will be issued indicating
it.