Installation manual
CNC 8055
CNC 8055i
8055 CNC CONFIGURATION
1.
SOFT: V02.2X
·29·
Central unit
1.2 Central unit
The central unit is usually located in the electrical cabinet, is modular and it comes in two models:
There are 2 models: for 3 and 6 modules.
The modules are mounted using the screws located at their top and bottom.
Available modules
CPU
It contains the system software and carries out the CNC functions (editing, execution, simulation,
display, etc.), process the information of the rest of the modules and generate the video signals for
the monitor.
Optionally, it communicates with the drives via Sercos interface.
It must be part of all the configurations and mounted as the first module from the left.
Axes
Besides controlling the spindle and the axes of the machine, it governs the first 40 digital PLC inputs
and 24 digital PLC outputs.
It must be present in all configurations. Together with the –CPU– module makes up the basic system
configuration.
I/Os
It is optional. It offers another 64 digital PLC inputs and 32 digital PLC outputs.
FAGOR
I/O
X1
X2
X3
I/O
X1
X2
X3
I/O
X2
X3
I/O
X1
X2
X3
AXES
X1 X2
X3 X4
X5 X6
X7 X8
X9
X10
CPU
X1 X2
CMPCT
FLASH
ETH
COM1
X3
C
D
E
F
0
B
A
9
8
1
7
2
6
3
5
4
IN
OUT
NODE
USB