·32·
Installation manual
CNC 8055
CNC 8055i
1.
8055 CNC CONFIGURATION
SOFT: V02.2X
Central unit
Central Unit (CPU) voltage supply
Power the central unit through a separate 110VA transformer with an output voltage between 84Vac
and 264Vac and 50-60 Hz.
1. Indicator led. When ON, it indicates that the central unit is under power.
2. Lithium battery. Maintains the RAM memory data when the system is powered off.
3. Mains plug. Is used to power the central unit by connecting it to the transformer and to ground.
4. Ground terminal. All ground terminals of the machine must be connected to this terminal. Metric
6mm.
When detecting a voltage peak, wait for 3 minutes before turning it on again.
For further technical information, refer to the appendix at the end of this manual. See "Central unit
of the 8055 CNC" on page 649.
Do not manipulate the inside of the unit.
Only authorized personnel from Fagor Automation may do it.
Do not handle the connectors with the unit connected to main AC power.
Before manipulating these connectors, make sure that the unit is not connected to main AC power.
FAGOR
I/O
X1
X2
X3
AXES
X1 X2
X3 X4
X5 X6
X7 X8
X9
X10
CPU
X1 X2
CMPCT
FLASH
ETH
COM1
X3
C
D
E
F
0
B
A
9
8
1
7
2
6
3
5
4
IN
OUT
NODE
USB
FAGOR
1
2
3
4

Table of Contents