8055 CNC CONFIGURATION
SOFT: V02.2X
Central unit
1.2.3 –Vpp SB Axes– module
The axes module is used in Sercos configurations and will appear in <DIAGNOSIS> /
<CONFIGURATION> / <HARDWARE> under the name of "SB axes module".
Besides controlling the spindle and the axes of the machine, it governs the 40 digital PLC inputs
and 24 digital PLC outputs. This module offers the following to communicate with the outside world:
2 Feedback inputs admitting single-ended and double-ended (differential) TTL signals as
well as 1Vpp sinusoidal signals.
2 Feedback inputs admitting single and double-ended (differential) TTL signals.
8 Analog command outputs for the servo drives.
4 Free differential analog inputs for controlling, monitoring or supervising systems.
2 Digital probe inputs.
24 Digital outputs ,optocoupled, commanded by the PLC.
40 Digital inputs ,optocoupled, read by the PLC.
Elements
Connectors ·X1· and ·X3·
SUB-D HD type 15-pin female connectors
for feedback systems of each axis. They
accept sinewave signals.
Connector ·X5·
SUB-D type 15-pin male connectos for
feedback system of the axes. Up to 2 axes
may be connected per connector. They do
not accept sinewave signals.
Connector ·X8·
SUB-D type 15-pin female connector to
connect up to 8 analog outputs (range
±10V).
Connector ·X7·
SUB-D type 15-pin male connector to
connect up to 4 differential analog inputs
(range ±10 V) and two probe inputs (TTL or
24 V).
Connector ·X10·
SUB-D type 37-pin female connector for the
8 digital inputs of the PLC and its 24 digital
outputs.
Connector ·X9·
37-pin male connector of the SUB-D type
for 32 digital inputs of the PLC.
Do not manipulate the inside of the unit. Only personnel authorized by Fagor Automation may access
the interior of this unit.
Do not handle the connectors with the unit connected to AC power. Before manipulating these
connectors, make sure that the unit is not connected to main AC power.
The machine manufacturer must comply with the "EN 60204-1 (IEC-204-1)", standard regarding
protection against electrical shock due to I/O contact failures with external power supply when not