EasyManua.ls Logo

Fagor CNC 8055i FL EN - Page 51

Fagor CNC 8055i FL EN
732 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation manual
CNC 8055
CNC 8055i
8055 CNC CONFIGURATION
1.
SOFT: V02.2X
·51·
Central unit
Signal adapters
The following signal adapters are available to be used with the –Vpp axes– module.
SA-TTL-TTLD Adapter for "Non-differential TTL" to "differential TTL" signals
SA-FS-P Adapter for Fagor sinusoidal signal to Vpp signal.
Technical characteristics of the feedback inputs
Power supply consumption of +5 V 1 A (250 mA per axis).
Work levels for differential square signal.
Work levels for non-differential square signal.
Work levels for sinusoidal signal.
Maximum frequency 500 kHz.
A and B signals Amplitude: 0.6 ÷ 1.2 Vpp
Centered: |V1-V2| / 2 Vpp =< 6,5%
Ratio: VApp / VBpp = 0.8 ÷ 1.25
Phase difference: 90º ± 10º
Reference mark (I0) signalAmplitude: 0.2 ÷ 0.85 V
Width: T-90º =< I0 =< T+180º
Maximum frequency: 1000 kHz.
Maximum gap between flanks: 460 ns.
Phase difference: 90º ± 20º.
Vmax in common mode: ± 7 V.
Vmax in differential mode: ± 6 V.
Hysteresis: 0.2 V.
Maximum differential input current: 3 mA.
Maximum frequency: 400 kHz.
Maximum gap between flanks: 460 ns.
Phase difference: 90º ± 20º.
High threshold (logic level "1") V
IH
: 1,25 V < V
IH
< 7 V.
Low threshold (logic level "0") V
IL
:-7 V < V
IL
< 1 V.
Vmax: ± 7 V.
Hysteresis: 0.25 V.
Maximum differential input current: 3 mA.
A
B
Io
V
1
VA
PP
V
2
VB
PP
VI
OPP

Table of Contents