Variables associated with the second spindle
13.11 Variables associated with the second spindle
Variables associated with the real speed
SSREAL
It returns the actual (real) turning speed of the second spindle. Its value is given in 0.0001 rpm units.
SFTEOS
It returns the theoretical turning speed of the second spindle.
Variables associated with spindle speed
The variable SPLCS is a read-write variable, the rest are read-only.
SSPEED
It returns the turning speed of the second spindle currently selected at the CNC. Its value is given
in 0.0001 rpm units.
This turning speed may be indicated by program, by PLC or by DNC; the CNC selects one of them,
the one indicated by DNC has the highest priority and the one indicated by program has the lowest
priority.
SDNCS
It returns the spindle speed selected via DNC. If it has a value of 0 it means that it is not selected.
SPLCS
It returns the spindle speed limit selected via PLC. If it has a value of 0 it means that it is not selected.
SPRGS
It returns the spindle speed limit selected by programa. If it has a value of 0 it means that it is not
selected.
Variables associated with constant cutting speed (lathe model)
The variable SPLCCSS is a read-write variable, the rest are read-only.
SCSS
It returns the constant surface speed selected at the CNC.
This constant surface speed may be indicated by program, by PLC or by DNC; the CNC selects one
of them, the one indicated by DNC has the highest priority and the one indicated by program has
the lowest priority.
The values are given in the units set by general parameter INCHES.
If INCHES = 0, in m/min (±999999999).
If INCHES = 1, in ft/min (±393700787).
SDNCCS
It returns the constant surface speed selected via DNC. Its value is given in m/min or ft/min and it
is 0 it means that it is not currently selected.
SPLCCS
It returns the constant surface speed selected by PLC. Its value is given in m/min or ft/min and it
is 0 it means that it is not currently selected.