·586·
Installation manual
CNC 8055
CNC 8055i
14.
AXES CONTROLLED FROM THE PLC
SOFT: V02.2X
PLC execution channel
Auxiliary M functions
The M functions programmed in the PLC channel may be defined in the M function table.
In the PLC channel, the following functions cannot be programmed: M0, M1, M2, M3, M4, M5, M6,
M19, M30, M41, M42, M43, M44 and M45.
The following marks and registers are generated for managing the M functions, :
MBCDP1 through MBCDP7 (R565 through R571)
similar to signals MBCD1 through MBCD7.
AUXENDP (M5006)
Similar to the AUXEND signal.
MSTROBEP (M5505)
Similar to the MSTROBE signal.