Installation manual
CNC 8055
CNC 8055i
8055 CNC CONFIGURATION
1.
SOFT: V02.2X
·59·
Central unit
Connectors and connection
Connectors X1, X2
37-pin male connectors of the SUB-D type used for the PLC inputs.
The 0V of the power supply used for these inputs must be connected to pins 18 and 19 of each
connector.
All shields must only be connected to ground at the CNC end leaving the other end free. The wires
of the shielded cable must not be longer than 75 mm without the protection shield.
Connector X1.
Pin Signal and function
1
2
3
4
5
- - -
I97
I99
I101
I103
6
7
8
9
10
I105
I107
I109
I111
I113
11
12
13
14
15
I115
I117
I119
I121
I123
16
17
18
19
20
I125
I127
0 V
0 V
- - -
External power supply.
External power supply.
21
22
23
24
25
I98
I100
I102
I104
I106
26
27
28
29
30
I108
I110
I112
I114
I116
31
32
33
34
35
I118
I120
I122
I124
I126
36
37
I128
Chassis - Shield.