CUSTOMIZABLE SCREENS
15.
SOFT: V02.2X
·597·
Key words
It is possible to define as many DISABLE instructions as screen areas are to be eliminated.
To eliminate the whole standard screen, program (DISABLE 0). In this case, only the OEM screen
will be displayed.
Examples:
;(WGDWIN 201)
It must ALWAYS be defined. It indicates the number of the OEM screen to be overlapped, edited
with the Fagor WINDRAW55 application software.
;(W1=GUP100)
Associates the value of a global parameter with the (W) data.
Standard screen OEM screen
Without "Disable"
Both screens overlap.
There are areas with information overlapped.
In this case, area 1.
With (DISABLE 1)
Area 1 of the standard screen is not displayed.
With (DISABLE 1) and (DISABLE 3)
Areas 1 and 3 of the standard display are not
displayed.
With (DISABLE 0)
All areas of the standard screen are turned off
Only the OEM screen is displayed.