Installation manual
CNC 8055
CNC 8055i
D.
SOFT: V02.2X
·655·
Probe connection at the 8055i
PROBE CONNECTION AT THE 8055i
The CNC has two probe inputs (of 5Vdc and 24Vdc) at connector X3.
Depending on the type of connection applied the general parameter "PRBPULSE" (P39) must be
set, indicating whether it operates with the leading edge or trailing edge of the signal which the probe
provides.
Probe with "normally open contact" output.
Probe with "normally closed contact" output.
Interface with an open-collector output. Connection to +5 V.
Interface with an open-collector output. Connection to +24 V.
Interface with a PUSH-PULL output
Acts with an up-flank.
Acts with an up-flank.
Acts with a down flank.
Acts with a down flank.
The active flank depends on the
interface used