Connectors and connection
Power
3-prong male Phoenix connector, 7.65 mm pitch.
Use an independent external power supply with the following specifications:
The central unit has a protection against overvoltage that activates at 36 V.
The supply current has the following shape on power-up:
Pin Signal and function
1 + 24 V Power supply.
2 0 V Power supply.
3 Chassis Shield.
Rated voltage 20 V minimum 30 V maximum
Ripple: 4 V
Nominal current 2 A
Current peak on power-up: 8 A