Installation manual
CNC 8060
CNC 8065
MACHINE PARAMETERS.
2.
(REF: 1402)
·67·
General machine parameters.
The double input/output module must be assigned two base indexes for the inputs and two
base indexes for the outputs; one for each board;
NUMBERING OF ANALOG INPUTS FOR TEMPERATURE
SENSORS PT100.
NPT100
Total number of active PT100 inputs.
Possible values: From 0 to 10.
Default value: 0 (there are no active PT100 inputs).
Associated variable: (V.)MPG.NPT100
This parameter indicates the number of PT100 inputs active in the CAN bus. A PT100 input
is active if it has one of these temperature sensors connected to it.
PT100
Table of active PT100 inputs.
This parameter shows the list of PT100 inputs active in the CAN bus.
PT100 n
Analog input associated with the PT100 input.
Possible values: From 0 to 32.
Default value: 0 (Do not activate the PT100 input).
Associated variable: (V.)MPG.PT100[nb]
When numbering the analog inputs, the CNC considers the PT100 inputs as analog inputs.
Therefore, when numbering the inputs, the CNC considers that each module has 6 analog
inputs; the four analog inputs plus the two PT100 inputs.
This parameter indicates the number of the analog input associated with each active PT100
input. Each parameter can take any valid value; there is no need to follow a particular order.
For example, in a system with two modules of analog inputs and 3 active PT100 inputs (the
two of the first module and the first one of the second module), the PT100 parameters may
be are set in one of the following ways.
Group ·1·
(address = 1)
Group ·2·
(address = 2)
Analog inputs. 1 ·· 4 7 ·· 10
PT100 inputs. 5 ·· 6 11 ·· 12
NPT100 PT100 1 PT100 2 PT100 3
Option 135611
Option 2 3 5 11 6
Option 336511
Option 4 3 6 11 5
Option 5 3 11 5 6
Option 6 3 11 6 5