Operating manual.
CNC 8060
CNC 8065
22.
SETUP ASSISTANCE
Oscilloscope
·408·
(REF: 1807)
If the machine parameters are protected, when accessing any of them, the CNC will display
a window requesting a password.
Variables that may be modified at the Sercos drive
Besides the parameters shown in the previous table, the user may access any variable
having a writing permission if he knows its name. To do this, use the following nomenclature:
Indicate the axis, the name of the parameter and the set separated by a period.
When modifying any parameter of the previous table, the change is effective immediately
without having to reset or restart the unit even when there is a program in execution.
The drive parameters modified with this method are functional immediately, but these values
will be lost when the drive is turned off. Use the "Save to flash" option to maintain the modified
values of those machine parameters.
Variables and parameters that may be modified at a
Mechatrolink device.
Access from the oscilloscope to variables and parameters of the device is only available for
the Mlink-II mode with 32 bytes. It is not possible to access the parameters and variables
of the same device at the same time.
MAXACCEL [ch].G.MAXACCEL Beginning of next block
MAXJERK [ch].G.MAXJERK Beginning of next block
SERVOOFF MPA.SERVOOFF[set].axis Immediate
Drive Name Update
CP1 CP1.axis Immediate
CP2 CP2.axis Immediate
CP3 CP3.axis Immediate
CP30 CP30[set].axis Immediate
CP31 CP31[set].axis Immediate
CP32 CP32[set].axis Immediate
NP1 NP1.axis Immediate
RP1 RP1.axis Immediate
RP2 RP2.axis Immediate
RP3 RP3.axis Immediate
RP4 RP4.axis Immediate
RP51 RP51.axis Immediate
RP52 RP52.axis Immediate
RP53 RP53.axis Immediate
RP54 RP54.axis Immediate
SP1 SP1[set].axis Immediate
SP2 SP2[set].axis Immediate
SP50 SP50.axis Immediate
SP51 SP51.axis Immediate
TP10 TP10.axis Immediate
TP11 TP11.axis Immediate
TP12 TP12.axis Immediate
TP13 TP13.axis Immediate
TP14 TP14.axis Immediate
CNC Drive Associated variable Update