Operating manual.
CNC 8060
CNC 8065
23.
DDSSETUP
–Information– service
·444·
(REF: 1807)
Types of inputs and outputs of a Sercos drive.
The inputs and outputs may be grouped as follows.
• Inputs and outputs that cannot be assigned. These inputs and outputs indicate the status
of the drive's control signals.
• Inputs and outputs that may be assigned. Variables and/or parameters of the drive may
be associated with inputs and outputs (analog and digital).
Those digital outputs that have not been associated with any parameter or variable may
be forced to become active or inactive using the button on the left of their led.
Speed enable Drive enable Error Reset
LSC Status DR. OK PROG. OK
Master Speed Enable Master Drive Enable Master Halt
Torque Status