·748·
Installation manual
CNC 8060
CNC 8065
10.
CNC VARIABLES.
(REF: 1402)
Variables related to synchronized switching.
10.29 Variables related to synchronized switching.
The value of these variables is equivalent to the one programmed in the parameters of the
instruction #SWTOUT. When executing the instruction without parameters and the variables
have a value assigned to it, the CNC assumes these latter values as active. Likewise, when
programming the parameters of the instruction, the variables assume these values as their
own.
On CNC power-up, the offset wears are set to zero. After power-up, the values programmed
for the offsets (using the instruction #SWTOUT or the variables) are maintained even after
an error, a reset or an M30.
These variables interrupt block preparation. To modify the offset values without interrupting
block preparation, change these values from the PLC or use the parameters of the instruction
#SWTOUT. If these variables are changed from the PLC, the new values are assumed when
executing the instruction #SWTOUT. If the instruction is active when changing the values
from the PLC, it assumes the new values.
V.G.TON
Variable that can be read and written via program, PLC and interface.
The variable returns the execution value; reading/writing it interrupts block preparation.
Time shift (milliseconds) to anticipate the activation of the digital output.
V.G.TOF
Variable that can be read and written via program, PLC and interface.
The variable returns the execution value; reading/writing it interrupts block preparation.
Time shift (milliseconds) to anticipate the deactivation of the digital output.
V.G.PON
Variable that can be read and written via program, PLC and interface.
The variable returns the execution value; reading/writing it interrupts block preparation.
Distance shift (offset, mm(inches) to anticipate the activation of the digital output.
V.G.POF
Variable that can be read and written via program, PLC and interface.
The variable returns the execution value; reading/writing it interrupts block preparation.
Distance shift (offset, mm(inches) to anticipate the deactivation of the digital output.
V.G.TON
V.G.TOF
V.G.PON