Hardware configuration.
CNC 8070
6.
CENTRAL UNIT + MONITOR (Q7-A PLATFORM).
Hardware functionality (connectors).
·110·
(REF: 1911)
·F2A· Protection fuse.
·H30A· / ·H30B· USB 2.0 Ports.
·H30C· USB 3.0 Port.
·H31B· Ethernet.
The module has a F2A (fast 2A) fuse that may be accessed
from the outside to protect against over-voltage (greater than
36 V DC or 25 V AC).
Type A, USB 2.0 connector.
Pin. Signal.
1+ 5 V
2DT -
3DT +
4GND
Do not run part programs from a USB device, whether it be when using a pendrive or external hard
drive. Fagor Automation recommends using the USB port only to exchanging data, such for programs,
reports, etc. If you require more storage space, then use a CFast disk.
DO NOT connect any kind of hub to the USB port.
Type A, USB 3.0 connector.
Pin. Signal.
1+ 5 V
2DT -
3DT +
4GND
5 StdA_SSRX-
6 StdA_SSRX+
7 GND_DRAIN
8 StdA_SSTX-
9 StdA_SSTX+
Do not run part programs from a USB device, whether it be when using a pendrive or external hard
drive. Fagor Automation recommends using the USB port only to exchanging data, such for programs,
reports, etc. If you require more storage space, then use a CFast disk.
DO NOT connect any kind of hub to the USB port.
See "6.8.6 Connection to an Ethernet network." on page 124.
8-pin RJ45 connector and 2 status LED's.
Pin. 10Base-T (10/100 Mhz). 1000Base-T (1000 Mhz).
1 TX+ (transmit data). BI_DA+
2 TX- (transmit data). BI_DA-
3 RX+ (receive data). BI_DB+
4 - - - BI_DC+
5 - - - BI_DC-
6 RX- (receive data). BI_DB-
7 - - - BI_DD+
8 - - - BI_DD-
A Connection LED. The LED turns on when the central unit is
connected to network.
B Activity LED. The LED blinks when data is being transferred.