Connector data.
Number of poles. 9.
Pitch. 2.5 mm.
Connection technique. Spring connection.
Minimum/maximum section. 0.14 / 0.5 mm².
Minimum/maximum AWG section. 26 / 20.
Rated current In. 4 A.
Cable data.
Length to be stripped. 8 mm.
See "6.7.1 Digital inputs." on page 115.
Plug-in part. 2 identical connectors 9-pole Phoenix-contact
minicombicon connector (2.5 mm pitch).
• Top connector.
• Bottom connector.
• Both connectors.
Pin. Signal. Function.
1
24 V 24 V DC voltage supply.
2 - 9 LI1 - LI8 Local digital inputs.
Pin. Signal. Function.
1
GND 0 V reference signal.
2- 9 LI9 - LI16 Local digital inputs.