Hardware configuration.
CNC 8070
CENTRAL UNIT + MONITOR (Q7-A PLATFORM).
6.
Technical/electrical characteristics of the inputs and outputs.
·117·
(REF: 1911)
Work levels for sinusoidal 1 Vpp signal.
Characteristic. Value.
Maximum frequency: 500 kHz.
A and B signals. Amplitude: 0.6 ÷ 1.2 Vpp
A and B signals. Centered: |V1-V2| / 2 Vpp =< 6,5%
A and B signals. Ratio: VApp / VBpp = 0.8 ÷ 1.25
A and B signals. Phase shift: 90º ± 10º
I0 signal. Amplitude: 0.2 ÷ 0.85 V
I0 signal. Width: T-90º =< I0 =< T+180º
A
B
Io
V1
V2
VApp
VBpp
VIopp