Hardware configuration.
CNC 8070
6.
CENTRAL UNIT + MONITOR (Q7-A PLATFORM).
Connections.
·120·
(REF: 1911)
6.8.4 Handwheel connection (only C70-10K).
The LCD-10K model admits the connection of up to 3 handwheels (MPG1, MPG2 and
MPG3) with A and B signals (5 V DC TTL). If he handwheel has an axis selector button, the
button signal may be connected to a digital input and may be managed from the PLC using
the -NEXTMPGAXIS-mark.
We recommend to run the handwheel cable as far away as possible from the power cables
of the machine.
Connector pinout.
10-pin male Phoenix-contact minicombicon connector (3.5 mm pitch).
Cable characteristics.
The cable being used must have overall shield. The unshielded portion of the wires of an
unshielded cable cannot be longer than 75 mm.
Pin Signal Function
1 +5 V Power supply.
2 - - - - - -
3 - - - - - -
4 MPG3-B B signal of the third handwheel.
5 MPG3-A A signal of the third handwheel.
6 MPG2-B B signal of the second handwheel.
7 MPG2-A A signal of the second handwheel.
8 MPG1-B B signal of the first handwheel.
9 MPG1-A A signal of the first handwheel.
10 GND Power supply.
Always connect the shield of the cable to the ground plate using a metallic clamp.
Ground plate.
Cable shield.
Handwheel cable.