Hardware configuration.
CNC 8070
CENTRAL UNIT FOR CABINET (Q7-A PLATFORM).
7.
Specifications.
·139·
(REF: 1911)
The machine manufacturer must comply with the EN 60204-1 (IEC-204-1) regulation
regarding electrical shocks in case of defective input/output pins with external power supply
when not plugging the connector before turning the power supply on.
Inputs/outputs. 16 opto-coupled digital inputs (24 V DC).
- IEC61131-2 type 1 and type 3 compliant.
8 opto-coupled digital outputs (24 V DC, 500 mA).
- ON cycle: minimum 75 µs (25 µs, optional in two of them).
1 analog outputs (±10 V, 16-bit resolution).
1 feedback inputs (5 V, 250 mA).
- Incremental TTL signal, differential TTL or 1 Vpp.
- Frequency: 100 kHz (TTL) / 1000 kHz (TTL differential) / 500 kHz (1 Vpp).
1 relay with one normally open contact (1A at 24V).
2 probe inputs (5 V or 24 V)
1 entry for UPS unit control.
Type. Description.
To help increase storage space, Fagor Automation lists several CFast cards in its catalog; when using
a third-party CFast, always use an industrial grade CFast SLC as these support temperatures from
between -40ºC and +85ºC (-40 ºF and 185 ºF) and can last five years with constant day-to-day writing.
Fagor Automation shall not be held responsible for any problems caused by using lower-quality CFast
cards.
Do not run part programs from a USB port, whether it be while using a pendrive or external hard drive.
Fagor Automation recommends using the USB port only to exchanging data, such for programs,
reports, etc. If you require more storage space, then use a CFast disk.
DO NOT connect any kind of hub to the USB port.