Hardware configuration.
CNC 8070
CENTRAL UNIT FOR CABINET (Q7-A PLATFORM).
7.
Hardware functionality (connectors).
·155·
(REF: 1911)
·X27· Relay for the emergency chain.
·I65· UPS control.
Connector data.
Number of poles. 2.
Pitch. 3.5 mm.
Connection technique. Spring connection.
Minimum/maximum section. 0.2 / 1.5 mm².
Minimum/maximum AWG section. 24 / 16.
Rated current In. 8 A.
Cable data.
Length to be stripped. 10 mm.
See "7.8.4 Connecting the relay for the emergency chain." on page
160.
Connector data.
Number of poles. 3.
Pitch. 3.5 mm.
Connection technique. Spring connection.
Minimum/maximum section. 0.2 / 1.5 mm².
Minimum/maximum AWG section. 24 / 16.
Rated current In. 8 A.
Cable data.
Length to be stripped. 10 mm.
See "16 CNC-FPS. FAGOR-UPS (Q7-A platform only)." on page
259.
Plug-in part. 2-pole Phoenix-contact minicombicon connector (3.5 mm
pitch).
Pin. Signal. Function.
1 RELAY Relay for the emergency chain.
2 RELAY Relay for the emergency chain.
Plug-in part. 3-pole Phoenix-contact minicombicon connector (3.5 mm
pitch).
Pin Signal. Function.
1 DISSABLE_BAT Potential-free relay.
2 DISSABLE_BAT Potential-free relay.
3 BAT_MODE UPS status.