Hardware configuration.
CNC 8070
7.
CENTRAL UNIT FOR CABINET (Q7-A PLATFORM).
Connections.
·160·
(REF: 1911)
7.8.3 Connecting the DVI-D video output.
Digital video output, with a maximum resolution of 1920×1200.
Characteristics of the DVI-D cable.
7.8.4 Connecting the relay for the emergency chain.
Single-contact relay, normally open contact that closes when the CNC is powered up and
running properly; it opens again when the CNC is turned off or when an internal failure occurs.
The relay withstands up to 1 A at 24 V.
Connector pinout.
Plug-in part. 2-pole Phoenix-contact minicombicon connector (3.5 mm pitch).
Characteristic. Description.
Type. Single link cable (18+1) or dual link cable (24+1) with triple shielding
and ferrite cores on both ends. Recommended reference; Digitus
AK-320101-050.
Maximum length. 5 meters (16.40 ft).
Pin. Signal. Function.
1 RELAY Relay for the emergency chain.
2 RELAY Relay for the emergency chain.